Agilent Technologies E4371A Lawn Mower User Manual


 
4 - User Interface
48
Raw log
Transfers all of the logged data in the order that it was logged.
Sorted by cell
Transfers all of the logged data sorted by cell. Data is organized from first
cell to last cell.
Individual
files per cell
Transfers all of the logged data and creates a separate data file for each cell.
4. When you select Raw log or Sorted by cell, you must enter a filename in which to store the data.
Select the Browse button to chose a directory in which to put the file. The default directory is
C:\hpmccd\bin
5. When you select Individual files per cell, the utility automatically creates up to 256 data files (one
for each active cell. Filenames are c001.txt through c256.txt. All files will be placed in the
C:\hpmccd\bin\data directory.
6. Click Transfer to start the data transfer. The status field provides status information about the
transfer.
7. Click Exit to exit the utility.
Data files that are created by the measurement log utility contain the following information:
cell-number
1 through 256
step-number
1 through n; the total number of steps in the sequence
time
Time in seconds since the forming sequence was triggered
status
A value that indicates the status of the cell
Value Status
1 constant voltage mode
2 constant current charge mode
4 constant current discharge mode
entry-type
One of the following: “Charge”, “Discharge”, “Rest”, “ACR”, “DCR”
volt-reading
Cell voltage in volts (only for Charge, Discharge, and Rest steps)
curr-reading
Cell current in amperes (only for Charge, Discharge, and Rest steps)
amp-hours
Cumulative ampere-hours from the beginning of the step-number (only for
Charge, Discharge, and Rest steps)
watt-hours
Cumulative watt-hours from the beginning of the step-number (only for
Charge, Discharge, and Rest steps)
resistance
ac or dc resistance measurement in ohms (only for ACR and DCR steps)