Tektronix TDS 310 Sprinkler User Manual


 
Command Descriptions
Syntax and Commands
2Ć142
RS232:TRANsmit:DELay
Sets or queries the minimum amount of time to wait after receiving a query
command before sending the response. This is provided for old terminals
and computers that cannot accept data immediately after sending data.
Miscellaneous
RS232: HARDFLAGGING, RS232:SOFTFLAGGING, RS232: STOPBITS,
RS232?
RS232:TRANsmit:DELay { <NR1> }
RS232:TRANsmit:DELay?
DELay
:
TRANsmit
:
RS232
<Space>
?
<NR1>
<NR1> the delay value from 0 s to 60 s.
RS232:TRANsmit:DELay 0
sets the transmit delay to 0 s.
RS232:TRANsmit:TERMinator
Sets or queries the endĆofĆline (EOL) terminator. When transmitting, the
oscilloscope appends the terminator to the end of each message. When
receiving, the oscilloscope accepts all four terminators, regardless of the
currently selected terminator. When a combination of multiple characters is
selected (CRLF or LFCR), the oscilloscope interprets the first character as the
terminator; it treats the second character as a null command.
CR represents an ASCII carriage return character (0x0D) and LF represents
an ASCII linefeed character (0x0A).
Miscellaneous
RS232: HARDFLAGGING, RS232:SOFTFLAGGING, RS232: STOPBITS,
RS232?
RS232:TRANsmit:TERMinator { CR | LF | CRLf | LFCr }
RS232:TRANsmit:TERMinator?
Group:
Related Commands:
Syntax:
Arguments:
Examples:
Group:
Related Commands:
Syntax: