Position
The horizontal position control establishes the time between the
trigger and the screen center. Refer to Horizontal Scale and Position;
Pretrigger Information on page 19 for more information on how to
use this control to position the trigger.
Slope and Level
The Slope and Level controls help to define the trigger. The Slope
option (Edge trigger type only) determines whether the oscilloscope
finds the trigger point on the rising or the falling edge of a signal.
The TRIGGER LEVEL knob control s where on the edge the trigger
point occurs.