When the analyzer sees a match between the state clock inputs and the slave
clock specification, Demux Slave data is latched. Then, followed by a match
of the state clocks and the master clock specification, the slave data is
strobed into analyzer memory along with the master data. If multiple slave
clocks occur between master clocks, only the data latched by the last slave
clock prior to the master clock is strobed into analyzer memory.
Latching Slave Data in Demultiplex Mode
Analyzer Memory
Slave Latch
Data on Master
Data on Slave
latches on Master Clock
latches on
Slave Clock
Same pod
The Format Menu
Pod Clock Field (State only)
4–11