The X Markers and the Markers Field
The Markers field is used to access the markers selection pop-up menu. The
choices available depend on the Count field in the Trigger menu. With Count
Off, only Sample and Pattern are available. With Count Time, Sample,
Pattern, Time, and Statistics are available. With Count States, Sample,
Pattern, and States are available.
Markers Field
Sample
The Sample selection turns X and O marker operations off, and enables the
X1 and X2 markers. The data values at the X1 and X2 markers are
automatically displayed to the right of the Marker field when charting label
versus state. Data between the X1 and X2 markers may be rescaled. For
more information on rescaling, refer to "Rescale" later in this chapter.
If a Compare Stop measurement is specified in the Stop measurement field,
and the Stop measurement criteria are met, the measurement will stop even
though the Markers are set to Sample. However, an X-O Stop measurement
will not complete if Markers are set to Sample.
Markers field
The Chart Menu
The X Markers and the Markers Field