Measurement and Display Functions
Arming
Each module can be armed by the RUN key, external PORT IN, or
by another module via the Intermodule Bus (IMB).
Displayed Waveforms
24 lines maximum, with scrolling across 96
waveforms.
Measurement Functions
Run/Stop Functions
Run
Starts acquisition of data in specified trace mode.
Stop
In single trace mode or the first run of a repetitive acquisition, STOP
halts acquisition and displays the current acquisition data. For subsequent
runs in repetitive mode, STOP halts acquisition of data and updates the
current display.
Trace Mode
Single mode acquires data once per trace specification.
Repetitive mode repeats single mode acquisitions until stop is pressed or
until time interval between two specified patterns is less than or greater than
a specified value, or within or not within a specified range.
Indicators
Activity Indicators
Provided in the Configuration and Format menus for
identifying high, low, or changing states on the inputs.
Markers
Two markers (X and 0) are shown as dashed lines on the display.
Trigger
Displayed as a vertical dashed line in the Timing Waveform display
and a line 0 in the State Listing display.
Specifications and Characteristics
Supplemental Characteristics
13–7