2-20 Radio PC Card Configuration
MX2 Reference Guide Revision A MX2A137REFGD
ODI with NetWare
Client
Complete the following steps to install the ODI drivers for NetWare
Client:
1. Start the Configuration Utility by double-clicking on the icon in the
Configuration Utility group on your PC.
2. From the Main Menu, select the Custom button.
3. An Open dialog box will appear (see screen displays in Chapter 4).
Select the PX_VLM.CFG configuration file. In the next Open
dialog box, select a program settings file. (If you do not have a
specific one that you want to use, select DEFAULT.PRS.)
The following files are included automatically as part of the Novell
TCP/IP download:
IPXODI.COM - IPZ/SPX driver
LSL.COM
- Link support layer driver
NET.CFG - ODI configuration file
RL2PCM.COM
- Proxim RF ODI Driver
VLM.EXE - Virtual loadable module manager
*.VLM - Virtual loadable modules
4. Select the File Configuration button in the Custom Configuration
menu.
5. Select the Add button, and use the File Selection dialog box (see
screen displays in Chapter 4) to include the main application and
additional files in your custom installation. Be sure to turn on the
Main Application switch for the one you want the MX2 to use.
6. Select the Next button at the bottom of the File Configuration
window.
7. In the second File Configuration window, make sure the Vendor
Specific option is selected. This option identifies which Phoenix
drivers to download.
Note: The I/O-card drivers are not compatible with
Proxim’s client driver. Do not select the I/O Cards
options when using RF.
8. Select the More button to verify that the DOS files you need are
included in the download. After viewing the file list and making any
necessary changes, return to the File Configuration window.