C-4 Default Settings
MX2 Reference Guide Revision A MX2A137REFGD
EAN/JAN
Enable EAN-8/JAN-8 On
Enable EAN-13/JAN-13 On
Convert EAN-13 to ISBN Off
Send EAN/JAN Checksum Off
UPC/EAN/JAN Extensions
Allow 2-Digit Extensions On
Allow 5-Digit Extensions On
Require Extensions Off
Other Controls
Autoterminator CR
Auto-Off Timer 5 min.
Send Symbology Identifier Off
Good-Read Beep Tone (in Hertz) 2400
Number of Good-Read Beeps 1
Good-Read Beep Duration (in seconds) 0.07
Beeper Volume Highest
Error Beep Tone (in Hertz) 2580
*Long-Range Trigger Mode Off (Spot Timeout)
*Spot Beam Timeout (in seconds) 0.5
*Release Scan Timeout (in seconds) 2
Spotting Beam Enable On
Keypress Sound Click
Enable Ctl-Alt-Del Reboot On
Enable Trigger Programmability
1
On
Backlight Auto-Off Timeout (in seconds) 15
Double Key Action Mode Double Strike
Double Key Action Timeout 330
*
(long-range scanner models only)
1
This parameter affects MX2 Enter key programmability.