Utility
MOTIF-RACK XS Owner’s Manual
101
Basic Structure
Voice
MultiUtility
Reference
The Controls &
Connectors
Setting Up
Listening to
the Sound
Connections
Using a Computer
Quick Guide
Appendix
Quick Setup dialog
This dialog allows you to execute the Quick Setup by selecting the Quick Setup Number and pressing the [ENTER] button.
1 Quick Setup Number
This parameter lets you select three types of settings registered to Quick Setup.
Three types of the Initial Settings are shown below.
Settings: 1 – 3
2 Quick Setup parameters (indication only)
Displays the parameters for Quick Setup.
3 Current settings for each parameter (indication only)
4 New settings after executing Quick Setup for each parameter (indication only)
Quick
Setup
Number
Application Parameters Other Settings
1
When recording performance data other than
Arpeggio data to a DAW software on a
computer.
Local control: off
MIDI: auto
Clock Out: off
Arp MIDI Out Sw: all off
Make sure that Echo Back (MIDI Thru) on the
DAW software is set to “on.”
2
When recording performance data including
Arpeggio data to a DAW software on a
computer.
Local control: on
MIDI: auto
Clock Out: off
Arp MIDI Out Sw: all on
Make sure that Echo Back (MIDI Thru) on the
DAW software is set to “off.”
3
When using the MOTIF-RACK XS as a stand-
alone device, without connecting to a DAW
software or other MIDI devices.
Local control: on
MIDI: internal
Clock Out: on
Arp MIDI Out Sw: all off
—
3 Controller
Determines Controller Assign settings common to the entire system of the MOTIF-RACK XS. You can assign MIDI Control Change Numbers
to the knobs on the front panel and the external controllers. For example, you could use the ASSIGN 1 and 2 knobs to control effect depth for
two different effects, while using the Foot Controller to control modulation. These Control Change Number assignments are known as
“Controller Assign.”
RB Ctrl No.
(Ribbon Control Number)
Determines the Control Change number corresponding to a Ribbon Controller on an external device
connected to the MOTIF-RACK XS.
Settings: off, 1 – 95
FC 1 Ctrl No.
(Foot Controller 1 Control Number)
FC 2 Ctrl No.
(Foot Controller 2 Control Number)
Determines the Control Change number corresponding to a Foot Controller on an external device
connected to the MOTIF-RACK XS.
Settings: off, 1 – 95
FS Ctrl No.
(Foot Switch Control Number)
Determines the Control Change number corresponding to a Foot Switch on an external device
connected to the MOTIF-RACK XS.
Settings: off, 1 – 95
AS 1 Ctrl No.
(Assign 1 Control Number)
AS 2 Ctrl No.
(Assign 2 Control Number)
Determines the Control Change number corresponding to the ASSIGN1 knob and ASSIGN2 knob
(when the lamp of bottom row is lit).
Settings: off, 1- 95