Toro 4042 Greenhouse Kit User Manual


 
Greensmaster eFlex 1800/2100 Page 4 -- 13 Electrical System
Traction Circuit Is Inoperative
NOTE: The parking brake latch has to be released, the
operator presence control has to be engaged and the
speed control has to be above the zero speed position
before the traction circuit will operate.
Possible Causes
Correction
Traction switch is not adjusted correctly or is faulty.
Speed control potentiometer is faulty.
Parking brake latch switch is not adjusted correctly or
is faulty.
Wire harness connections or wires are loose or
damaged.
A problem exists with the traction or reel drive system.
Electric motor is faulty (NOTE: Fault should be
displayed on InfoCenter if electric motor is faulty).
Use InfoCenter Diagnostics screen to check traction
switch operation. Adjust or replace traction switch if
necessary.
Use InfoCenter Diagnostics screen to check speed
control potentiometer operation. Check and repair
speed control potentiometer and circuit wires if
necessary.
Use InfoCenter Diagnostics screen to check p arking
brake latch switch operation. Adjust or replace parking
brake latch switch if necessary.
Check electrical connections. Repair wire harness as
necessary.
Refer to Chapter 3 -- Traction and Reel Drive System.
Use InfoCenter Faults and Diagnostics screens to
check reel circuit operation. Check electric motor and
circuit wires. Repair as necessary.
Cutting Reel Circuit Is Inoperative
Possible Causes Correction
Reel engage switch is not adjusted or is faulty.
Wire harness connections or wires are loose or
damaged.
Electric motor is faulty (NOTE: Fault should be
displayed on InfoCenter if electric motor is faulty).
Use InfoCenter Diagnostics screen to check reel
engage switch operation. Adjust or replace reel
engage switch if necessary.
Check electrical connections. Repair wiring as needed.
Check electric motor and circuit wires. Repair as
necessary.
Electrical
System