Toro 4042 Greenhouse Kit User Manual


 
Greensmaster eFlex 1800/2100 GroomerPage 7 -- 7
Service and Repairs
Groomer Belt Replacement (Forward Rotating Groomer Drive)
1. Parkmachineonlevelsurface.Turnkeyswitchtothe
OFF position and remove key from the switch. Make
sure the traction lever is in the NEUTRAL position.
2. Disconnect the b attery pack (see Battery Pack Con-
nection in the General Information section of this chap-
ter).
3. Remove three (3) lock nuts that secure groomer
drive cover, then remove cover (Fig. 3).
4. Pivot idler pulley by placing a 12mm wrench on
pulley nut and rotating idler bracket to relax belt tension.
Slip groomer drive belt off pulleys (Fig. 4). Carefully re-
lease idler bracket.
IMPORTANT: Make sure that the drive belt is cen-
tered on the pulleys and correctly aligned with
pulley grooves after installation.
5. Install new drive belt to drive pulley, idler pulley and
driven pulley observing correct belt routing (Fig. 4).
6. Secure belt cover to machine with three (3) lock nuts
(Fig. 3).
7. Connectthe battery pack(see Battery Pack Connec-
tion in the General Information section of this chapter).
1. Groomer drive cover 2. Lock nut (3 used)
Figure 3
1
2
1. Drive pulley
2. Idler pulley
3. Idler pulley nut
4. Driven pulley
5. Groomer drive belt
Figure 4
1
2
3
4
5