LG Electronics C Series Portable Generator User Manual


 
Chapter 9. Basic functions
9.3 Run Command setting
z Run via the Run and STOP/RST key
Group LED Display Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
drv
[Drive mode]
(Run/Stop mode)
0
0/3 1
Drive
group
drC
[Direction of motor
rotation select]
- F/r F
Set drv – [Drive mode] to 0.
Motor starts to accelerate by pressing the Run key while run frequency is set. Motor decelerates to
stop by pressing the STOP/RST key.
Selecting rotation direction is available at drC - [Direction of motor rotation select] when run
command is issued via Run key on keypad.
FX : Counter clockwise
F Forward
drC [Direction of motor
rotation select]
R Reverse
z Run command setting 1 via FX and RX terminals
Group LED Display Parameter Name
Set
Value
Min/Max
Range
Factory
Defaults
Unit
Drive
group
drv
[Drive mode]
(Run/Stop mode)
1
0/3 1
I20
[Multi-function input
terminal P1 define]
0 0/24 0
I/O
group
I21
[Multi-function input
terminal P2 define]
1 0/24 1
Set drv – [Drive mode] to 1.
Set I20 and I21 to 0 and 1 to use P1 and P2 as FX and RX terminals.
“FX” is Forward run command and “RX” Reverse run.
Operation will stop when both FX and RX terminals are turned ON or OFF.
FX
RX
Frequency
66