LG Electronics C Series Portable Generator User Manual


 
Chapter 7. Function list
I/O group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
I 0 [Jump code] 0/63 This parameter sets the code number to jump. 1 O 5-5
I 1 [Filter time
constant for
V0 input]
0/9999 This is used to adjust the analog voltage input
signal via keypad potentiometer.
10 O
I 2 [V0 input Min
voltage]
0/10
[V]
Set the minimum voltage of the V0 input. 0 O
I 3 [Frequency
corresponding
to I 2 ]
0/400
[Hz]
Set the inverter output minimum frequency at
minimum voltage of the V0 input.
0.0 O
I 4 [V0 input Max
voltage]
0/10
[V]
Set the maximum voltage of the V0 input. 10 O
I 5 [Frequency
corresponding
to I 4]
0/400
[Hz]
Set the inverter output maximum frequency at
maximum voltage of the V0 input.
60.0 O
9-2
I 6 [Filter time
constant for
V1 input]
0/9999 Set the input section’s internal filter constant
for V1 input.
10 O
I 7 [V1 input Min
voltage]
0/10
[V]
Set the minimum voltage of the V1 input. 0 O
I 8 [Frequency
corresponding
to I 7]
0/400
[Hz]
Set the inverter output minimum frequency at
minimum voltage of the V1 input.
0.0 O
I 9 [V1 input max
voltage]
0/10
[V]
Set the maximum voltage of the V1 input. 10 O
I10 [Frequency
corresponding
to I 9]
0/400
[Hz]
Set the inverter output maximum frequency at
maximum voltage of the V1 input.
60.0 O
9-3
I11 [Filter time
constant for I
input]
0/9999 Set the input section’s internal filter constant
for I input.
10 O
I12 [I input
minimum
current]
0/20
[mA]
Set the Minimum Current of I input. 4 O
9-4
I13 [Frequency
corresponding
to I 12]
0/400
[Hz]
Set the inverter output minimum frequency at
minimum current of I input.
0.0 O
I14 [I input max
current]
0/20
[mA]
Set the Maximum Current of I input. 20 O
I15 [Frequency
corresponding
to I 14]
0/400
[Hz]
Set the inverter output maximum frequency at
maximum current of I input.
60.0 O
0 Disabled
1 Less than half the value set in I 2/7/12
entered
I16 [Criteria for
Analog Input
Signal loss]
0/2
2 Below the value set in I 2/7/12 entered
0 O 12-7
0 Forward run command {FX} I20 [Multi-function
input terminal
P1 define]
1 Reverse run command {RX}
0 O 9-7
2 Emergency Stop Trip {EST} I21 [Multi-function
input terminal
P2 define]
3 Reset when a fault occurs {RST}.
1 O
4 Jog operation command {JOG} 10-3 I22 [Multi-function
input terminal
P3 define]
5 Multi-Step frequency – Low
2 O
6 Multi-Step frequency – Mid I23 [Multi-function
input terminal
P4 define]
0/24
7 Multi-Step frequency – High
3 O
9-6
52