LG Electronics C Series Portable Generator User Manual


 
Chapter 7. Function list
I/O group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
I42 [Multi-Accel
time 5]
7.0
I43 [Multi-Decel
time 5]
7.0
I44 [Multi-Accel
time 6]
8.0
I45 [Multi-Decel
time 6]
8.0
I46 [Multi-Accel
time 7]
9.0
I47 [Multi-Decel
time 7]
9.0
10[V] Output Output item
200V 400V
0 Output
frequency
Max frequency
1 Output current 150 %
2 Output voltage 282 V
I50 [Analog output
item select]
0/3
3 DC link voltage DC 400V
0 O
I51 [Analog output
level
adjustment]
10/200
[%]
100 O
11-5
I52 [Frequency
detection
level]
30.0 O 11-6
I53 [Frequency
detection
bandwidth]
0/400
[Hz]
This parameter is used when I54 – [Multi-
function output terminal select] or I55 –
[Multi-function relay select] are set to 0-4.
It cannot be set greater than F21 – [Max
frequency].
10.0 O
0
FDT-1 11-6
I54 [Multi-function
output
terminal
select]
1
FDT-2
12
11-6
2 FDT-3 11-8
3 FDT-4 11-8
4 FDT-5 11-9
5 Overload {OL}
6 Inverter Overload {IOL}
7 Motor stall {STALL}
8 Over voltage trip {OV}
9 Low voltage trip {LV}
10 Inverter heatsink overheat {OH}
11 Command loss
11-9
12 During run
13 During stop
14 During constant run
15 During speed searching
16 Wait time for run signal input
I55 [Multi-function
relay select]
0/17
17 Fault relay output
17
O
11-
10
When
setting the
H26–
[Number of
auto
restart try]
When the
trip other
than low
voltage trip
occurs
When the
low voltage
trip occurs
Bit 2 Bit 1 Bit 0
0 - - -
1 - -
3
2 -
3
-
3 -
3 3
4
3
- -
I56 [Fault relay
output]
0/7
5
3
-
3
2 O 11-6
54