14. Specifications
command, H/W fault
Alarm
Conditions
Stall prevention, Overload
Momentary
power loss
Less than 15 msec: Continuous operation
More than 15 msec: Auto Restart enable
z Environment
Cooling
method
Forced air cooling
Degree of
protection
Open, Pollution degree 2
Ambient
temperature
-10 ~ 50°C (14 ~ 122°C)
Storage
temperature
- 20 ~ 65°C (-4 ~ 149°C)
Relative
humidity
Less than 90% (no condensation)
Altitude,
Vibration
1,000m (3000 ft) above sea level, Max. 5.9m/sec
2
(0.6G)
Application
site
Protected from corrosive gas, combustible gas, oil mist or dust
14.2 Temperature Derating Information
z Load current VS Carrier frequency
For 2.2kW inverter
For 0.4kW, 0.8kW, 1.5kW inverter
Load
Current
Load
Current
100%
100%
80%
1kHz 15kHz
1kHz
8kHz
15kHz
Carrier freq. Carrier freq.
Note:
1. The above graph is applied when inverter is in use within the permissible ambient
temp. If the unit is installed in a panel, install it where heat dissipation is properly done
to keep the panel ambient temp within permissible range.
2. This de-rating curve is based on inverter current rating when rated motor is connected.
123