LG Electronics C Series Portable Generator User Manual


 
Chapter 5. Programming keypad
5. Programming Keypad
5.1 Keypad features
Buttons
z RUN
z STOP/RST
z 4-WAY BUTTON
z Potentiometer
Display
z FWD/REV LED
z 7 Segment LED
Display
FWD Lit steadily during forward run
REV Lit steadily during reverse run
Blinks when a fault occurs
7-Segment
(LED Display)
Displays operation status and parameter information
Keys
RUN Used to give a run command
STOP/RST STOP: Stop the operation RST: Reset faults
4-WAY BUTTON Programming keys (UP/Down/Left/Right arrow and Prog/Ent keys)
S UP Used to scroll through codes or increase parameter value
T Down Used to scroll through codes or decrease parameter value
W Left Used to jump to other parameter groups or move a cursor to the left to change
the parameter value
X Right Used to jump to other parameter groups or move cursor to the right to change
the parameter value
z
Prog/Ent
key
Used to set the parameter value or save the changed parameter value
Potentiometer Used to change the value of run frequency
25