LG Electronics C Series Portable Generator User Manual


 
Chapter 7. Function list
CHAPTER 7 - Function list
Drive Group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
0.0
[Frequency
command]
0/400
[Hz]
This parameter sets the frequency that
the inverter is commanded to output.
During Stop: Frequency Command
During Run: Output Frequency
During Multi-step operation:
Multi-step
frequency 0.
It cannot be set greater than F21- [Max
frequency].
0.0 O 9-1
ACC [Accel time] 5.0 O 9-10
dEC [Decel time]
0/6000
[sec]
During Multi-Accel/Decel operation, this
parameter serves as Accel/Decel time 0.
10.0 O 9-10
0
Run/Stop via Run/Stop key on the
keypad
9-7
1
FX: Motor forward run
RX: Motor reverse run
2
Run/Stop
via control
terminal
FX: Run/Stop enable
RX: Reverse rotation select
9-7
Drv [Drive mode]
(Run/Stop
mode)
0/3
3 Operation via Communication Option
1 X
0 Setting via Keypad 1 9-1
1
Digital
Setting via Keypad 2 9-1
2
Setting via potentiometer on
the keypad (V0)
9-2
3 Setting via V1 terminal 9-3
4 Setting via I terminal 9-3
5
Setting via potentiometer on
the keypad + I terminal
9-4
6 Setting via V1 + I terminal 9-4
7
Setting via potentiometer on
the keypad + V1 terminal
9-5
Frq [Frequency
mode]
0/8
8
Analog
Modbus-RTU
Communication
0 X
St1 [Multi-Step
frequency 1]
This parameter sets Multi-Step frequency 1
during Multi-step operation.
10.0 O 9-6
St2 [Multi-Step
frequency 2]
This parameter sets Multi-Step frequency 2
during Multi-step operation.
20.0 O 9-6
St3 [Multi-Step
frequency 3]
0/400
[Hz]
This parameter sets Multi-Step frequency 3
during Multi-step operation.
30.0 O 9-6
CUr [Output
current]
This parameter displays the output current to
the motor.
- - 11-1
rPM [Motor RPM] This parameter displays the number of Motor
RPM.
- - 11-1
dCL [Inverter DC
link voltage]
This parameter displays DC link voltage inside
the inverter.
- - 11-1
This parameter displays the item selected at
H73- [Monitoring item select].
vOL Output voltage
POr Output power
vOL [User display
select]
tOr Torque
vOL - 11-2
nOn [Fault Display] This parameter displays the types of faults,
frequency and operating status at the time of
the fault
- - 11-2
This parameter sets the direction of motor
rotation when drv - [Drive mode] is set to
either 0 or 1.
F Forward
drC [Direction of
motor rotation
select]
F/r
r Reverse
F O 9-7
43