LG Electronics C Series Portable Generator User Manual


 
Chapter 7. Function list
I/O group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
6
3 3
-
7
3 3 3
I60 [Inverter
station
number]
1/32 This parameter is set when the inverter
uses RS485 communication.
1 O
Select the Baud rate of the RS485
0 1200 bps
1 2400 bps
2 4800 bps
3 9600 bps
I61 [Baud rate]
0/4
4 19200 bps
3 O
It is used when frequency command is
given via V1 and I terminal or communication
option.
0 Continuous operation
1 Free Run stop (Coast to stop)
I62 [Drive mode
select after
loss of
frequency
command]
0/2
2 Decel to stop
0 O
I63 [Wait time
after loss of
frequency
command]
0.1/12
[sec]
This is the time inverter determines
whether there is the input frequency
command or not. If there is no frequency
command input during this time, inverter
starts operation via the mode selected at I62.
1.0
-
12.7
55