Chapter 4 - Parameter Description [I/O]
70
[FDT-1]
When the output frequency reaches the reference
frequency (target frequency), MO-MG terminal is
CLOSED.
[MO-MG configured as ‘FDT-1’]
[FDT-2]
MO-MG is CLOSED when the reference
frequency is in I/O-43 [FDT Bandwidth] centered
on I/O-42 [FDT Frequency], and the output
frequency reaches I/O-43 centered on I/O-42.
[MO-MG configured as ‘FDT-2’]
[FDT-3]
MO-MG is CLOSED when the output frequency
reaches the band centered on the FDT frequency.
The output is OPENED when the output
frequency goes outside the FDT bandwidth
centered on the FDT frequency.
[MO-MG configured as ‘FDT-3’]
[FDT-4]
MO-MG is CLOSED when the output frequency
reaches the FDT frequency. The output is
OPENED when the output frequency goes below
the FDT bandwidth centered on the FDT
frequency.
[MO-MG configured as ‘FDT-4’]
[FDT-5]
This is the inverted output of [FDT-4].
[MO-MG configured as ‘FDT-5’]