Aquacal 75003 Swimming Pool Pump User Manual


 
PROGRAMMING AND OPERATION
35
MENUS (For the Installer Menu, press and hold SELECT button for approximately 13 seconds to access this feature)
Programming the system remote (Used when interfaced to communicate with electronic control systems)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Select remote” is displayed, then press SELECT.
3. Select Remote 1 or Remote 2, depending on the electronic control system being connected to, then press SELECT.
Remote 1 is used for most electronic control systems with a universal communication program.
Remote 2 is used for controllers with a modified communication program, such as Jandy Aqualink Rev. L
4. Press
or until “End menu mode” is displayed, then press SELECT.
Programming the system mode (Used when controlling the pH or Pool Chemistry Controller optional components)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Select system” is displayed, then press SELECT (Purifier is the factory setting).
3. The display will show the current configuration;
Purifier – sanitizer production only
pH Control – pH acid feeder option #’s 75004, 75005, 75006, or 75007 is installed with #75003 Pool Pilot Digital
Total Control - #75001 Pool Chemistry Controller and acid feeder options are installed with the #75003 Pool Pilot
Digital
4. Press
or until the desired configuration is reached, then press SELECT.
5. Press
or until “End menu mode” is displayed, then press SELECT.
pH and Total Control Menus (Only applicable with optional acid feeder installed)
Activating the Boost acid mode
(Used to override the pH m a ximum (pg 36) sh ut -off protection feature, and activate the pH feed
pump to a specified amount of acid solution, in oz., ml, or liters, to lower the pH when there is acid solution in the storage tank)
1. Press MENU, press
or until “Owner Options” is displayed, then press SELECT.
2. Press
or until “Boost acid” is displayed, then press SELECT.
3. Press
or to assign the amount of acid solution needed (1 oz to 250 oz (29 ml to 7.4 L)), then press SELECT.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Prime acid pump (used to test for leaks or to fill acid feed tubing during maintenance or installation)
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Prime acid pump” is displayed, then press SELECT.
3. The display will show “
- Start Pump”. Press arrow up (a 180 second count down timer will display).
4. Once activated, the display will show
“Press any key to stop pump XXX”.
If any leaks are detected, press any panel key (button) to immediately stop the pump.
5. Otherwise, the acid pump will continue to prime until the countdown timer ends or is manually stopped.
Reset acid meter (used to reset the acid meter display to 0)
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Reset acid meter” is displayed, then press SELECT.
3. The display will flash to verify “
Acid meter reset”.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Enable / Disable acid (used to enable or disable the acid feed pump)
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Enable acid or Disable acid” is displayed, then press SELECT.
if “Enable acid” then the acid pump is disabled, press SELECT to enable the acid pump.
if “Disable acid” then the acid pump is enabled, press SELECT to disable the acid pump.
3. Press
or until “End menu mode” is displayed, then press SELECT.
! Warning
Do not operate the acid pump until the leak is repaired. See enable/disable acid below