Aquacal 75003 Swimming Pool Pump User Manual


 
INSTALLATION
13
Optional 115 Volt configuration
230 Volt factory configuration
Electrical Connections
The Pool Pilot Digital uses both high and low voltage connection s . High vo ltage connections will be made for providing the
direct input power to it. Additional high voltage connections may be made to the filter pump from the Pool Pilot Digital. Low
voltage connections will be made to the Tri-Sensor and SuperCell. Additional low voltage connections are provided for optional
equipment such as #75008 pH feeder, #75001 Pool Chemistry Controller, or an ORP or electronic control.
! DANGER
Ensure that power is disconnected before wiring this unit.
Follow all state / local / NEC (CEC if applicable) electrical codes.
Use copper conductors only.
Grounding and Bonding
Connect a ground wire from the primary electrical input to the grounding lug located inside the box. Also ground any piece of
high voltage equipment that is connected to the Pool Pilot Digital relay.
The Pool Pilot Digital must also be connected to the pool bonding system with an 8AWG (6AWG for Canada) wire. A lug is
provided on exterior of the unit at the bottom.
High Voltage Wiring
Converting from 230 Vac to 115Vac
The #75003 Pool Pilot Digital h a s been configured at the factory for
230Vac service. Verify that this is the desired input voltage
configuration.
If 115Vac input power is required, follow the directions below to
convert the input voltage.
If the cover has not been removed, review the steps in
Mounting the #750 03 Pool Pilot Digital on pg. 12 for
instructions on removing the cover and disconnecting
the cable plugs at the display board.
Remove the single jumper wire and re-attach as shown
in the diagram.
Locate the jumper wire provided in the installation kit
and attach as shown in the diagram.