Aquacal 75003 Swimming Pool Pump User Manual


 
PROGRAMMING AND OPERATION
33
MENUS (For the Installer Menu, press and hold SELECT button for approximately 13 seconds to access this feature)
Programming the SuperCell to activate a Force reverse cycle for testing (Used to verify if the Digital unit is reversing polarity
(self cleaning)). There is a 30 second delay before reversing takes place after you End menu mode.
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Force reverse” is displayed, then press SELECT.
3. “Cell reversing” will display temporarily.
4. Press
or until “End menu mode” is displayed, then press SELECT.
5. The “
.”(period ) on the en d of 2
nd
line of the display will either appear or disappear based on its previous state to indicate
that the cell has reversed.
Programming the SuperCell reverse time (self cleaning) cycle
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Set reverse time” is displayed then press SELECT (4 hours is the factory setting).
3. Press
or until the desired cycle time (2, 4, 8, or 16 hours) is displayed, then press SELECT.
Warning: Shorter cycle times can reduce the SuperCell life and should only be changed due to uncontrollable
scale formation on the SuperCell.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Programming the unit to enable or disable a remote electronic control system by the Jandy, Polaris or Pentair electronic control
systems (Used only when wired to operate through the electronic control system)
1. Press MENU, press
or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Enable remote or Disable remote” is displayed
if “Enable remote” then the electronic controller is disabled, press SELECT to enable the electronic controller.
if “Disable remote” then the electronic controller is enabled, press SELECT to disable the electronic controller.
3. Press
or until “End menu mode” is displayed, then press SELECT.
Replace Cell (Used to reset the ampere-hour counter after a cell is replaced)
1. Press MENU, press
or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Replace Cell” is displayed, then press and hold SELECT for 13 seconds. “Amp-hours = zero” will
be momentarily displayed.
3. Press
or until “End menu mode” is displayed then press SELECT.
Programming the unit to Set prime protect (Range: No prime protect, 1-, 2-, 4-, 8- m i nutes) (used to provide protectio n against
potential damage of a one-speed pump by loss of prime and will shut down pump, chlorine, and acid feed operation if there is a
loss of flow for a user programmed time period – “No prime protect” is the factory setting)
Caution: Damage to equipment caused by a loss of prime to the pump system is not covered under warranty. The prime
protection feature is designed to assist in preventing damage. However, conditions beyond the control of the Digital Control
System may still allow damage to occur!
1. Press MENU, press or until “Maintenance menu” or “Installer menu” is displayed, then press SELECT.
2. Press
or until “Set prime protect” is displayed, then press SELECT.
3. Press
or to adjust to the desired length of time before prime protect activates, then press SELECT.
4. Press
or until “End menu mode” is displayed then press SELECT.