Aquacal 75003 Swimming Pool Pump User Manual


 
PROGRAMMING AND OPERATION
34
MENUS (For the Installer Menu, press and hold SELECT button for approximately 13 seconds to access this feature)
Calibrating the salt sensor.
Note: The unit has been calibrated at the factory and should not need further adjustments. In the event that the salt display does
not match on-site test results, follow these steps:
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Calibrate salt” is displayed, then press SELECT.
3. Press
or until the number on the display matches the accurately measured pool sample, then press SELECT. The
maximum adjustment is ± 1000 ppm (1.0 g/l).
4. Press
or until “End menu mode” is displayed, then press SELECT.
Calibrating the temperature display to match another thermometer (Used only when it is desired to match the display of the
Digital to another thermometer display)
1. Press MENU, press or until “Maintenance menu” is displayed, then press SELECT.
2. Press
or until “Calibrate temp.” is displayed, then press SELECT.
3. Press
or to adjust temperature up or down to the desired temperature, then press SELECT. The maximum
adjustment is ± 6
o
F (± 3
o
C). (To maximize protection, only negative adjustments will be used to calculate freeze
protection temperature.)
4. Press
or until “End menu mode” is displayed, then press SELECT.
Program the pool volume. (Must be programmed for the “salt amount needed” display to be accurate)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Set pool volume” is displayed, then press SELECT (Factory setting is 15,000 gallons).
(The range is 500 to 127,500 gallons (1,000 to 226,000 liters)
3. Press
or until correct pool size is displayed, then press SELECT.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Program the cell type. (Must match the installed cell)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Set cell type” is displayed, then press SELECT (Factory setting is SC-48).
3. Press
or until the correct SuperCell type is displayed “SC-36, SC-48, SC-60, CC-15”, then press SELECT.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Changing the output cell power level (See recommendations on pg. 29 for when to change cell power. Factory setting is Cell
Power 2)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Set cell power” is displayed, then press SELECT.
3. Press
or until desired level “Cell power 1, 2 or 3” is displayed, then press SELECT.
4. Press
or until “End menu mode” is displayed, then press SELECT.
Programming the Set relay 1 function (Used when the Digital is used to control the main circulation pump or pH acid feed pump)
1. Press MENU, press or until “Installer menu” is displayed, then press and hold SELECT for 13 seconds.
2. Press
or until “Set Relay 1” is displayed, then press SELECT (Relay not used is the factory setting).
3. The display will show the current configuration;
Relay not used – pump is controlled by an external time clock, controller or switch
One-speed – single speed pump is wired and programmed to the Digital
Two-speed – two speed pump is wired and programmed to the Digital
Acid pump – only when the main pump is not controlled by the Digital and the pH control option is installed
4. Press
or until the desired configuration is reached, then press SELECT.
5. Press
or until “End menu mode” is displayed, then press SELECT.