Xantrex Technology GT5.0-NA Portable Generator User Manual


 
Specifications
A–2 975-0320-01-01
Electrical Specifications
Input
Output
Input voltage, Maximum Power Point range 240 to 550 Vdc
Absolute maximum array open circuit voltage 600 Vdc
Maximum input current 22.0 Adc
Maximum array short circuit current 24 Adc
Reverse polarity protection Short circuit diode
Ground fault protection GF detection, I
DIF
> 1 A
Maximum output power 5000 W AC
Nominal output voltage 240 V
Operating range, utility voltage*
* Factory settings can be adjusted with the approval of the utility. This
unit is provided with adjustable trip limits and may be aggregated
above 30 kW on a single Point of Common Coupling. See “Adjustable
Voltage, Frequency and Reconnection Settings” on page A–3.
211 to 264 Vac
Nominal output frequency 60 Hz
Operating range, utility frequency* 59.3 to 60.5 Hz
Startup current 0 Aac
Maximum continuous output current 21 A
Output overcurrent protection 30 A RMS
Maximum utility backfeed current 0 A
Total Harmonic Distortion <5%
Power factor >0.95%
Utility monitoring— islanding protection Vac, fac as per UL 1741 (2005)
Output characteristics Current source
Output current waveform Sine wave