Xantrex Technology GT5.0-NA Portable Generator User Manual


 
Monitoring the Inverter
5–6 975-0320-01-01
Offline Mode
Offline default
display
At night and when no power is being produced by the PV array (offline mode), the
GT Inverter displays the screen shown in Table 5-5.
Offline messages
for all systems
Additional message screens can be viewed when the system is offline by tapping
the Xantrex logo near the LCD. Each additional tap displays the next screen, in
the order shown in Table 5-6.
These message screens are common to all GT Inverter systems, no matter how
many units are installed. If you continue to tap the unit, then the LCD will
continue to cycle through all of the available offline mode screens.
Additional Offline
messages for
multiple unit
systems
Multiple unit systems in offline mode display all of the message screens shown in
Table 5-6, plus the additional screens shown in Table 5-7. These additional
screens are displayed following the “Time Online” screen.
These screens are only displayed on multiple unit GT Inverter systems with
communications cables installed. If you continue to tap the unit, then the LCD
continues to cycle through all of the available offline mode screens.
Table 5-5
Offline Mode Default Display
Display Description
Inverter
Offline
Displayed at all times while the system is offline.
Table 5-6
Offline Mode Screens for All GT Inverter Units
Tap Display*
* In a multiple unit system with communications cables properly installed, the
system values displayed are for the entire system. Time online is for the local
inverter.
Description
1st time Inverter
Offline
LCD back light turns on for better readability
and default Offline Mode screen is displayed.
2nd time System 0W
Today 2.50kWh
Power being produced by the system now.
Cumulative energy produced by the system
today.
3rd time System Lifetime
305kWh
Lifetime energy produced by the system.
4th time Time Online
hh:mm:ss
Total time that the system was online today, in
hours (hh), minutes (mm) and seconds (ss).