Xantrex Technology Automatic Generator Portable Generator User Manual


 
Operation
4–8 975-0082-01-01
Hibernate mode
Characteristics Hibernate mode removes power from the Auto Gen Start and all Xanbus-
enabled devices on the Xanbus system. The Auto Gen Start suspends all
operations (including starting and stopping the generator) until power is
restored to the network.
If there are active faults in the system, you cannot put the system into
Hibernate mode. Clear any active faults, correct the condition that caused
the fault, then put the system into Hibernate mode.
Restoring
power
Once the system is in Hibernate mode, you must restore power to the
network manually.
If an inverter/charger supplies power to the network, you can bring the
system out of Hibernate mode either by pressing the reset button on the
inverter/charger front panel or by applying AC input to the inverter/
charger with utility power or generator power.
Viewing the Firmware Revision Number
You may need to view the firmware revision number when
troubleshooting the Auto Gen Start with authorized service personnel.
To view the firmware revision number:
1. On the Select Device menu, use the down arrow button to highlight
System.
2. Press Enter.
The System Settings menu appears.
3. Press the down arrow button to highlight View Device Info.
4. Press Enter.
The Device Info screen appears.
5. If Auto Gen Start screen is not already displayed, press the down
arrow button until it appears.
The number opposite “F/W Rev.” is the firmware revision number.
6. Press Exit to return to the System Settings menu.
Important:
Put the system into Hibernate mode before putting your RV or
boat in storage. This will prevent the Auto Gen Start from starting the generator
while unattended.