Toro 3010 Lawn Aerator User Manual


 
Accumulator Cap Wrench - TOR4003 (Fig. 4)
After discharging accumulator, use this special wrench
to remove accumulator cap for accumulator rebuilding.
Figure 4
Water System Pressure Gauge - TOR4005 (Fig. 5)
The Water System Pressure Gauge and Adapter is
temporarily connected into the high pressure water
system for measuring water pressure available to the
water valve.
Figure 5
Flow Meter - TOR4006 (Fig. 6)
The in-line flow meter with a battery-powered electronic
digital display is installed in the water supply line to
measure pump efficiency. The flow meter is equipped
with a pressure gauge to measure inlet water pressure.
This gauge used in conjunction with the pressure gauge
on the machine can be used to measure pressure drop
across the filter to show filter condition.
Figure 6
HydroJect 3010 Page 6 - 5 Special Tools