Performance Verification
4-8
AWG510 & AWG520 Service Manual
Table 4-1: Diagnostic categories and error codes (Cont.)
Categories DescriptionsError codes
Sequence Memory 5100
5101 to 5116
Data bus test error
DATA00 to DATA15 fail (DATA00: 5101)
5150
5151 to 5174
Address bus test error
ADD00 to ADD23 fail (ADD00: 5151)
5200
5201 to 5206
CS test error
CS0 to CS7 fail (CS0: 5201)
5250
5251 to 5256
Cell test error
CHIP0 to CHIP5 (CHIP0: 5501)
Waveform memory (CH1) 5300
5301 to 5316
Data bus test error
DATA00 to DATA15 fail (DATA00: 5301)
5350
5351 to 5374
Address bus test error
ADD00 to ADD13 fail (ADD00: 5351)
5400
5401 to 5464
Module test error
Refer to Finding Faulty Modules on page
4-10 for detail.
5500
5501 to 5549
Cell test error
Refer to Finding Faulty Modules on page
4-10 for detail.
Waveform memory
(CH1 or CH2)
5600
5601 to 5616
Data bus test error
DATA00 to DATA15 fail (DATA00: 5601)
5650
5651 to 5674
Address bus test error
ADD00 to ADD23 fail (ADD00: 5651)
5700
5701 to 5764
Module test error
Refer to Finding Faulty Modules on page
4-10 for detail.
5800
5801 to 5849
Cell test error
Refer to Finding Faulty Modules on page
4-10 for detail.
ARB DAC (CH1) 5900
5901 to 5912
ARB DAC test error
DATA00 to DATA11 fail (DATA00: 5901)
ARB DAC (CH1 or CH2) 5950
5951 to 5962
ARB DAC test error
DATA00 to DATA11 fail (DATA00: 5951)