CABINET HEATERS INSTALLATION, COMMISSIONING, OPERATION AND SERVICE MANUAL
4
Figure 1: Installation Clearances and Clearances to Combustibles
WARNING
Fire Hazard
Some objects will catch fire or explode when
placed close to heater.
Keep all flammable objects, liquids and
vapours the required distance away from the
heater.
Failure to follow these instructions can result
in death, injury or property damage.
*.6 m *.6 m
.6 m
4 m
.6 m
.6 m
The flue pipe must have clearance from combustibles by 5 cm.
If installed where individuals can come in contact with the pressure relief door or other hot components,
adequate guarding must be provided.
All distances are minimum clearance requirements for service access, air flow and safety.
*A service clearance of 1m is required on one side to allow for fan replacement.