Buhler 535 Lawn Mower User Manual


 
435/485/535
3-37
Section 3 - Operation
EIC - Tractor Performance Monitor (TPM)
F3-48
SPEED
PTO RPM
AREA
START
STOP
HOUR
AREA
FT
% SLIP
DISTANCE
SELECT
Selectable Display Information
The following information may be selected for
display:
Area Per Hour Forecaster
(see page 3-43 for calibration)
Area Per Hour Forecast is displayed by pressing the
AREA button (1) or toggling the SELECT button. The
“AREA/HOUR” legend (2) will display, together with a
forecast of the area that will be worked in one hour (3)
if the current rate of work is continued.
This forecast is based on the last 5 seconds running
average. The forecast may be in acres (FT) (4) or
hectares (METERS).
The unit of measure can be changed between FT/
METER. See “EIC programming” in this section.
NOTE: If the radar option is not installed, area per
hour calculations are based on axle speed and are
subject to inaccuracies caused by wheel slip that may
be present.
Area Accumulator (see page 3-43 for calibration)
Accumulated area (total area worked) (5) is displayed
by depressing the AREA button (1) until “AREA” and
“ON” (6) will be displayed. Area is displayed in acres
or hectares. Touch the START/STOP
button (7) and
the word “OFF” (8) will display indicating the area
counter is shut off. Toggle between Area Per Hour and
Area Accumulator by pressing AREA button (1)
NOTE: A remote implement status switch
P/N: 9702509, can also be added to the tractor, by
the use of a harness located under the rear frame next
to the trailer plug. RF049B (green wire) and RF144
(black wire) (9). If extra length is needed a harness
can be purchased from you Local Buhler Versatile
dealer: P/N 86034242. In order for the harness to
work, the wire located on the tractor trailer plug pin
4 must be disconnected and the expose wire covered
with electrical tape. The green wire RF049C must be
installed into pin 4 of the tractor trailer socket. By
adding a contact switch to a trailing implement, the
area counter can be turned on and off by lowering and
raising the implement.
English display (acres), designated by “FT” legend
(10) starts to accumulate in increments of 0.1 acres.
When 1000 acres are reached, area accumulation
continues in whole acres. When 9999 acres are
reached, the display will reset to zero.
F3-49
SPEED
PTO RPM
AREA
START
STOP
OFF
AREA
ON
FT
% SLIP
DISTANCE
SELECT
2 13
4
6 5
7
10
1
8
F3-136
9