Baldor ID101F50-E Yard Vacuum User Manual


 
1-4
General Information
Specifications
Horse Power
0.5 - 1 HP @ 1
15VAC, 1PH
0.5 - 5 HP @ 230V
AC, 3PH
1 - 5 HP @ 460V
AC, 3PH
Input V
oltage
95 - 127 V
AC, 50/60Hz, Single Phase
187 - 253V
AC, 50/60Hz, Three Phase
342 - 506V
AC, 50/60Hz, Three Phase
Phase Imbalance
(3Phase Only)
±2%
Input Frequency
50/60Hz (
±10%)
Enclosure
NEMA 1
Output V
oltage
0 to Maximum Input AC V
oltage
Output Frequency
0.1 to 400 Hz
Output Current
See Control Rating T
able
Service Factor 1.0
Duty Cycle Continuous
Overload Capacity
See Control Rating T
able
Control Method
V
oltage V
ector PWM
Carrier Frequency
9.2kHz
Frequency Resolution
0.05Hz
V/Hz Ratio
0.24 - 8.85 (230V
AC)
0.48 - 17.69 (460V
AC)
Output T
ransistor Type
IGBT (Insulated Gate Bipolar T
ransistor)
Transistor Rise Time
2500Volts/msec (dv/dt)
T
orque Boost
Standard (automatic adjustment to load)
Manual (0-15% of input voltage)
V
olts/Hertz Pattern
Linear to Squared Reduced (in 6 patterns)
Accel/Decel Time
0.1 to 600 seconds (for 2 assignable)
Base Frequency
26 to 960 Hz
Dynamic Brake Torque
Up to 60% for 6 seconds