Baldor ID101F50-E Yard Vacuum User Manual


 
3-2
Operation
STOP Push to initiate a stop command. Depending on the
setup of the control the motor will either ramp (Regen) or Coast
to Stop. See 41-Accel/Decel/Coast Select in Section 3 for more
information.
FWD Used to initiate a forward direction run of the motor.
REV Used to initiate a reverse direction run of the motor.
PROG Used to access Level 1 Parameters. Holding the SHIFT
key then pressing the PROG key will access Level 2
Parameters. If in the Run Mode the control will only allow
viewing of the parameter values. Any attempt to change a
parameter value while in the Run Mode will result in the display
showing “-----”. If in the Stop Mode pressing PROG or holding
SHIFT then pressing PROG will enter the Programming Mode at
Level 1 and Level 2 Parameters respectively. Pressing the
PROG key while in the Programming Mode will return the control
to the Stop Mode.
SHIFT Used in the Program Mode to allow changing of a
parameter value. While in Program Mode, the factory preset
value may be reset for any parameter by pressing the SHIFT key
then the UP and DOWN ARROW keys simultaneously. The New
parameter value is stored when the ENTER key is pressed.
UP ARROW
Used to change the displayed parameter or
parameter value up one increment. In the Programming Mode
the displayed parameters or parameter values will increment up
until the highest possible value is reached. The UP Arrow is also
used to increment the set speed in the Stop Mode and increment
the actual speed in the Run Mode. The value will increase at a
faster rate after holding the UP Arrow key for 5 seconds.
Pressing SHIFT while holding the UP Arrow will bypass the 5
second delay.
DOWN ARROW Used to change the displayed parameter or
parameter value down one increment. In the Programming Mode
the displayed parameters or parameter values will increment
down until the lowest possible value is reached. The DOWN