Baldor ID101F50-E Yard Vacuum User Manual


 
Operation
3-15
35-Preset Speed #3 - Sets the output frequency when Preset
Speed #3 is commanded at the Control Terminal Strip. The
adjustable range is 0.1-400 Hz. The factory setting is 40 Hz.
36-Preset Speed #4 - Sets the output frequency when Preset
Speed #4 is commanded at the Control Terminal Strip. The
adjustable range is 0.1-400 Hz. The factory setting is 60 Hz.
37-Preset Speed #5 - Sets the output frequency when Preset
Speed #5 is commanded at the Control Terminal Strip. The
adjustable range is 0.1-400 Hz. The factory setting is 0 Hz.
38-Preset Speed #6 - Sets the output frequency when Preset
Speed #6 is commanded at the Control Terminal Strip. The
adjustable range is 0.1-400 Hz. The factory setting is 0 Hz.
Note: Preset Speed adjustments set the commanded frequency
to be output from the control when the appropriate preset
speed is initiated. Preset speeds can be initiated by
external command at the control terminal strip. Since a
preset speed only sets an operating speed, a motor
direction command will also need to be initiated in order
for the motor to have rotation.
39-Min Freq Torque Limit - Sets the lowest output frequency
the inverter will output when in torque limit. If the motor loading
is large enough to drive the inverter below this output frequency,
the inverter will trip on an overcurrent fault (F16, F17 or F18).
The adjustable range is 0-400 Hz and the factory setting is 10
Hz. To disable torque limit set a value greater than the
frequency setting in parameter 32- Max Output Frequency. The
rate of deceleration in torque limit is set by parameter 46-Decel
Time Torque Limit.