Baldor ID101F50-E Yard Vacuum User Manual


 
2-14
Installation
2 Wire Run/Stop Connections
Parameter 21 - Operating Mode = 2 or 3
Parameter 41 - Accel/Decel/Coast select = 0, 1, 2, 4, 5 or 6
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Speed
Select
Speed Select
Speed Select
J19
Pull–Up
Logic
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Speed
Select
Speed Select
Speed Select
J19
Pull–Down
Logic
See recommended tightening torques for terminal connectors.
Speed Select
PS3
PS2 PS1 Function
Open Open Open Keypad or
Analog Command Input
Open Open Closed 33 - Preset Speed #1
Open Closed Open 34 - Preset Speed #2
Open Closed Closed 35 - Preset Speed #3
Closed Open Open 36 - Preset Speed #4
Closed Open Closed 37 - Preset Speed #5
Closed Closed Open 38 - Preset Speed #6
Closed Closed Closed 32 - Max Output Frequency