Baldor ID101F50-E Yard Vacuum User Manual


 
Operation
3-3
Arrow is also used to decrement the set speed in the Stop Mode
and decrement the actual speed in the Run Mode. The value will
decrease at a faster rate after holding the DOWN Arrow key for 5
seconds. Pressing SHIFT while holding the DOWN Arrow will
bypass the 5 second delay.
ENTER Used to store a new parameter value when in the
Programming Mode. Also used in the Run and Stop Modes to
store the current output frequency as the initial output frequency
when power is applied to the inverter.
Keypad Status Indicator
The STATUS indicator consists of two LED’s, one green and one
red. They are visible through a lens in the upper right hand
corner of the keypad. The following table defines the STATUS
indicator state for the various operating conditions of the inverter.
STATUS INDICATION
OPERATING CONDITION
Continuous displays
Green and Red Power on, Restart (2 Seconds)
Red Stop, Running in Torque Limit
Green Run
Intermittent Displays
Alternate Green and
Red Blinking
Running in and out of Torque Limit
Green Blinking Running in and out of an Overvoltage
or Undervoltage condition
Red Blinking Fault Condition, Emergency Stop,
Auto Restart Lock-out, Low Voltage