Baldor ID101F50-E Yard Vacuum User Manual


 
3-6
Operation
Program Mode
Use the Program Mode to customize the control to suit a variety
of applications by programming the operating parameters. From
the Stop Mode press the PROG key to access the Level 1
Program Mode. Hold the SHIFT key and press the PROG key to
access the Level 2 Program Mode. When in the Program Mode
press the SHIFT key then the UP/DOWN Arrow keys to change
a parameter value. Pressing the ENTER key will save the new
parameter value. To return to the Stop Mode, press the PROG
key. Parameters may only be programmed when accessed from
the Stop Mode. If entering the Programming Mode from the Run
Mode the parameter values may only be viewed.
Security Access/Lockout
Access to the control parameters can be protected by use of the
security code. Security is enabled, and the Security Code is
defined by setting parameter 87-Security Access Code. If the
Security Access Code is enabled and the Programming Mode is
entered then the following display is shown to prompt for the
previously defined Security Code. After the proper Security
Code is entered, the display will return to the normal
Programming Mode Display.
Control Operation Adjustment
The following control adjustments are available within the Series
10 inverter to allow custom tailoring of the drive for particular
applications. Table NO TAG user parameters lists the location
and possible values of the various control adjustments. The
following paragraphs discuss control parameter adjustments and
their effect on drive performance.