C 9.92
Operating Instructions
104 153 146
Operating the attachments
NOTE
An hydraulic accumulator pressure under 30
bar (light equipment) will require too many
control operations as the accumulator can not
function yet.
Applications with hydraulic accumulator
NOTE
If the attachment adjusts to ground uneven-
ness with a delay, reduce the relief pressure
or HYS.1.
- For light attachments (eg rotary mower) turn the
hydraulic accumulator off.
Switching the hydraulic accumulator off
- Press key (5), select float position or operate the
joystick. The LED indicator (7) will extinguish.
65
7
431 2
Bild_C188