11. FUNCTIONAL CHECK of EACH COMPONENT
11-l CONTROL PANEL
11-l-l ENGINE SWITCH
Using the circuit tester. check continuity across the black
and green top terminals of the 6P coupler.
When continuity between the termmals is confirmed with
the engine switch turn2d off. the switch is normal. It is also
normal if there is no continuity between thrse terminals,
when the engine switch is set at RUN or CHOKE position.
Fig. 11-l
1 l-l-2 FREQUENCY METER
Also check with the circuit tester. th2 continuity across the
yellow and blue top tsrminals of the 6P coupler. If con-
tinuity is confirmed between these terminals. the frequency
meter is normal.
Fig. 7 l-2
11-1-3 PILOT LIGHT
Using the circuit tester, check continuity between the red
and yellow top terminals of the 6P coupler.
Fig. 1 l-3
- 25 -