Agilent Technologies n3306a Portable Generator User Manual


 
B - Performance Test and Calibration
80
6. Set power source voltage and current values as listed in following table.
N3302A N3303A N3304A N3305A N3306A
Power Source Voltage Setting 24V 96V 12V 30V 12V
Power Source Current Setting 7A 3A 7A 15A 8A
7. Wait 15 seconds. Calculate and record resistance range 2 high resistance point
Resistance Range 3 Programming Accuracy
1. Press [ RES ]. Scroll until display reads RES:RANG, for models N3302A, N3304A, N3305A and N3306A press
[ 1 ] [ 0 ] [ 0 ] then [ Enter ]. For model N3302A press [ 5 ] [ 0 ] [ 0 ] then [ Enter ].
2. Checking resistance range 3, low resistance point. Press [ RES ] [select resistance from following table ] [ Enter ].
N3302A N3303A N3304A N3305A N3306A
36 440 18 45 9
3. Set power source voltage and current values as listed in following table.
N3302A N3303A N3304A N3305A N3306A
Power Source Voltage Setting 40V 96V 20V 50V 20V
Power Source Current Setting 3.5A 1A 3A 3.5A 3.5A
4. Wait 7 seconds. Calculate and record resistance range 3 low resistance point.
5. Checking resistance range 3, high resistance point. Press [ RES ] [select resistance from following table ] [ Enter ].
N3302A N3303A N3304A N3305A N3306A
400 4800 200 500 100
6. Set power source voltage and current values as listed in following table.
N3302A N3303A N3304A N3305A N3306A
Power Source Voltage Setting 40V 96V 20V 50V 20V
Power Source Current Setting 3.5A 1A 3A 3.5A 3.5A
7. Wait 7 seconds. Calculate and record resistance range 3 high resistance point.
Resistance Range 4 Programming Accuracy
1. Press [ RES ]. Scroll until display reads RES:RANG, For models N3302A, N3304A, N3305A and N3306A press
[ 1 ] [ 0 ] [ 0 ] [ 0 ] then [ Enter ]. For model N3303A press [ 5 ] [ 0 ] [ 0 ] [ 0 ] then [ Enter ].
2. Checking resistance range 4 low resistance point. Press [ RES ] [select resistance from following table ] [ Enter ].
N3302A N3303A N3304A N3305A N3306A
360 4400 180 450 90
3. Set power source voltage and current values as listed in following table.
N3302A N3303A N3304A N3305A N3306A
Power Source Voltage Setting 50V 96V 20V 50V 20V
Power Source Current Setting 3.5A 1A 3A 3.5A 3.5A
4. Wait 3 seconds. Calculate and record resistance range 3 low resistance point.
5. Checking resistance range 4, high resistance point. Press [ RES ] [select resistance from following table ] [ Enter ].
N3302A N3303A N3304A N3305A N3306A
2000 12,000 2000 2500 1000