Agilent Technologies n3306a Portable Generator User Manual


 
5 - Front Panel Operation
64
10. On the Function keypad, press Input On/Off to turn input on. Dis annunciator off
11. To make minor changes to an existing value: On the Function keypad, press
Current. On the Entry keypad, press Q
QQ
QInput or R
RR
R Input to scroll from 1.25 to
2.25. Then press Enter.
CURR 2.25
Set the constant resistance mode input
Action Display
1. On the Function keypad, press Q Channel to scroll through the channels until
channel 1 appears on the display.
1
2. On the Function keypad, press Input On/Off to turn input off.
Dis annunciator on
3.
On the Function keypad, press Func. On the Entry keypad, press Q Input or
R Input key until the resistance function is displayed, then press Enter.
FUNC:RES
4. On the Function keypad, press Res. On the Function keypad, press Q key until
resistance is displayed.
RES
5. On the Entry keypad press 50 Enter.
RES 50
6. On the Function keypad, press Res. On the Function keypad, press Q key until
resistance transient is displayed.
R:TLEV
7.
On the Entry keypad press 40 Enter.
R:TLEV 40
8. On the Function keypad, press Input On/Off to turn input on.
Dis annunciator off
9. To make minor changes to an existing value: On the Function keypad, press Res.
On the Entry keypad, press Q
QQ
QInput or R
RR
R Input to scroll from 50 to 60. Then press
Enter.
RES 60
Set the constant voltage mode input
Action Display
1.
On the Function keypad, press Q Channel to scroll through the channels until
channel 1 appears on the display.
1
2. On the Function keypad, press Input On/Off to turn input off.
Dis annunciator on
3. On the Function keypad, press Func. On the Entry keypad, press Q Input or
R Input key until the voltage function is displayed, then press Enter.
FUNC VOLT
4. On the Function keypad, press Voltage. On the Function keypad, press Q key until
voltage is displayed.
VOLT
5.
On the Entry keypad press 6 Enter.
VOLT 6
6.
On the Function keypad, press Voltage. On the Function keypad, press Q key until
voltage slew is displayed.
V:SLW
7. On the Entry keypad press 30000 Enter.
V:SLW 30000
8. On the Function keypad, press Voltage. On the Function keypad, press Q key until
voltage transient is displayed.
V:TLEV
9.
On the Entry keypad press 4 Enter.
V:TLEV 4
10.
On the Function keypad, press Input On/Off to turn input on.
Dis annunciator off
11. To make minor changes to an existing value: On the Function keypad, press
Voltage. On the Entry keypad, press Q
QQ
QInput or R
RR
R Input to scroll from 6.000 to
7.000. Then press Enter.
VOLT 7.000