Agilent Technologies n3306a Portable Generator User Manual


 
Front Panel Operation - 5
61
Transient Control Keys
Transient control keys control the transient functions of the electronic load.
Press this key to access the function menu.
Display Command Function
TRAN <value> Sets the current of input
T:DCYC Sets the current mode to FIX or LIST
T:FREQ Sets the current slew rate for both positive and negative transitions
T:MODE Sets the current slew rate for the negative transitions
T:TWID Sets the current slew rate for the positive transitions
Trigger Control Keys
Trigger control keys control the trigger functions of the electronic load.
Press this key to access the function menu.
Display Command Function
INIT:IMMED Sets the current of input
ABORT Sets the current mode to FIX or LIST
List Control Keys
List control keys control the list functions of the electronic load.
Press this key to access the function menu.
Display Command Function
LIST:STEP Sets the method of incrementing steps (ONCE, AUTO)
LST:CNT Specifies the number of times the list is cycled
DWEL:0 EOL Specifies the time period of each step
CURR:0 EOL Specifies the current setting for each step
C:RANG:0 EOL Specifies the current range for each step
C:SLEW:0 EOL Sets the current slew rate for each step
C:SLW:N:0 EOL Sets the negative current slew rate for each step
C:SLW:P:0 EOL Sets the positive current slew rate for each step
C:TLEV:0 EOL Sets the transient input current for each step
FUNC:0 EOL Sets the list regulation mode (CURR, RES, VOLT)
RES:0 EOL Specifies the resistance setting for each step
R:RANG:0 EOL Specifies the resistance range for each step
R:SLEW:0 EOL Sets the resistance slew rate for each step
R:SLW:N:0 EOL Sets the negative resistance slew rate for each step
R:SLW:P:0 EOL Sets the positive resistance slew rate for each step
R:TLEV:0 EOL Sets the transient input resistance for each step
TRAN:0 EOL Enables/disables the transient level for each step
T:DCYC:0 EOL Sets the transient duty cycle for each step
T:FREQ:0 EOL Sets the transient frequency for each step
T:MODE:0 EOL Sets the mode of the transient generator (CONT, PULSE)
T:TWID:0 EOL Sets the transient pulse width for each step
VOLT:0 EOL Specifies the voltage setting for each step
V:RANG:0 EOL Specifies the voltage range for each step
V:SLEW:0 EOL Sets the voltage slew rate for each step
V:SLW:N:0 EOL Sets the negative voltage slew rate for each step
V:SLW:P:0 EOL Sets the positive voltage slew rate for each step
V:TLEV:0 EOL Sets the transient input voltage for each step
Tran
Trigger
Control
List