42 Physical Controls
MX3-CE Reference Guide E-EQ-MX3CERG-G-ARC
USB Port
USB connection is made through an optional USB Serial Port if installed. The connector is an
industry-standard 9-pin “D” male connector.
The optional LXE USB cable is required to adapt the connection to a standard USB connector.
Please refer to section titled “Accessories” for the USB part number when ordering.
Figure 2-5 MX3-CE Serial Port
MX3-CE Connector Pin SIGNAL USB Connector Pin
1 Not Used 1 Not Used
2 Not Used 2 From 7
3 To 3 D + (Green Wire) 3 From 3
4 Not Used 4 From 5
5 To 4 Ground (Black Wire) 5 Not Used
6 Not Used 6 Not Used
7 To 2 D - (White Wire) 7 Not Used
8 Not Used 8 Not Used
9 Not Used 9 Not Used
Figure 2-6 USB-Serial Cable Pinouts
Tethered Scanners
The MX3-CE Scan buttons have no effect on tethered barcode scanners (connected to a serial
port). Tethered scanners read barcode scans only when the trigger on the tethered scanner is
pressed.
To set the MX3-CE to use a tethered scanner, select Start | Settings | Control Panel | Scanner |
COM1 (or 2 or 3).
Click the "Power on Pin 9 (+5V)" checkbox for the COM port selected. The COM port that
accepts the scanner data can be configured for data rate, parity, stop bits and data bits.