MAINTENANCE LBI-39128
31
REPORT SELECTION MENU
1. RETURN TO OPERATION SELECT MENU
2. ALARM REPORT
3. ALARM HISTORY
4. CURRENT STATUS
5. CHANNEL MONITOR
6. CHANNEL-ON TIMERS
7. CHANNEL DUMP
ENTER SELECTION:
Figure 23 - Report Selection Menu
ALARM HISTORY REPORT
SITE - NOT PROGRAMMED
TIME 2:50pm DATE 1/18
UNIT CHANNEL DESCRIPTION VALUE TYPE(S) TIME DATE
AI06 AI006 TX06 29.4 Watts F L 2:49pm 1/18
AI25 AI025 ANT01 0.0 Watts F L 2:49pm 1/18
Press any key to continue (Esc to abort)
Figure 24 - Alarm History Report Screen
10:32am 2/03 CHANNEL M O N I T O R REPORT
Esc aborts Timeout in 15 min
UNIT CHNL DESCRIPTION ALARMS VALUE UNITS ONTIME UPLIMIT LOLIMIT
AI01 AI001 TXO1 101.3*WATTS 50.0 125.0
Figure 25 - Channel Monitor Screen
The second part of the screen is a real time display of
the calculated value. It may take a while to get used to the
unlabeled format. Only one value is usually shown at a time.
A number with one decimal place is a power calculation. A
number with two decimal places is an SWR calculation. A
number from 15 to 1 is the time remaining until screen times
out.
Calculations are made every 250 milliseconds during
the time the associated transmitter is keyed. This includes
the first 750 milliseconds after a transmitter is keyed, when
alarm conditions are not reported to the Site Controller
computer. Therefore, you may briefly see a value that
exceeds the alarm limit and notice that no alarm is sent to
the Site Controller computer.
Connect the terminal to the PMU and access the PMU
as described under the PMU Programming heading in the
Installation section of this manual. Then use the following
procedure to access the Channel Monitor screen:
Calculated Power or
Calculated SWR
Selected
Analog Input Channel or
Analog Pseudo Channel