Sensor interface module in the EDACS Repeater
cabinet containing the transmitter for channel #11 or
#13). If the two cabinets are next to each other in the
same row, use a 5-ft 19D903880P120 cable. If the two
cabinets are across from each other in different rows,
use a 15-ft 19D903880P121 cable.
10. Starting with the cabinet containing the transmitter for
channel #11 or #13, follow the daisy chain of 25-pair
cabinet interconnect cables connected to J14 and J15 on
the Power Sensor interface module in each EDACS
Repeater cabinet until an empty J14 or J15 connector is
found. Plug the 19C852379G1 Channel Termination
Board (removed in the previous step) into this empty
connector.
11. Remove a shorting jumper in the 19C852379G1
Channel Termination Board for each transmitter
channel # equipped with a power sensor (P# plus 12
corresponds to transmitter channel #). Note that the P#
corresponds to a different transmitter channel # in this
case.
Note that there is a shorting jumper for transmitter
channels #11 and #12 on each of the 19C852379G1
Channel Termination Boards. Therefore, if transmitter
channel #11 or #12 is equipped with a power sensor, a
jumper must be removed from each of the two channel
termination boards.
12. Connect the five new 188D6466P2 cables from J3
through J7 on the Power Sensor interface module in the
upper EDACS Interface Panel, to Port 1 through Port 5
respectively on the back of the PMU.
13. Connect the new 188D6466P1 cable from J8 on the
Power Sensor interface module in the upper EDACS
Interface Panel, to PORT 7 on the back of the PMU.
14. If the Site Controller computer has modular RJ11-8
connectors on its back panel, connect the new
19D903880P101 cable from the right-hand VDT
Interface on the back of the PMU, to Port 29 on the
back of the Site Controller computer.
If the Site Controller computer does not have modular
RJ11-8 connectors on its back panel, connect the new
19D903880P100 cable from the right-hand VDT
Interface on the back of the PMU to connector #13 on
the right-hand (B) DILOG panel (above the Site
Controller computer).
15. Install the 19C336861P3 or P4 antenna power sensor(s)
at the output of the transmitter combiner(s) in the RF
Equipment cabinet(s).
16. Install the 19C852677P1 antenna power sensor cable
from J9 on the Power Sensor interface module in the
Site Controller cabinet, to the antenna power sensor(s)
in the RF equipment cabinet(s) as shown in Figure 9. If
the system has only one antenna, tack solder a jumper
(tip to shield) on each of the unused phono plugs to
short the forward and reflected power sensor circuits for
antenna #2.
1
6
2
3
4
7
8
9
High
Ground
Forward
Forward
Reflected
Reflected
Antenna #1
Antenna #2
High
Ground
High
Ground
High
Ground
DB-9 (F)
J9
DB-9 ( M)
POWER SENSOR
19C852632G1
Antenna Power Sensor Cable
Antenna Power Sensors
to Interface Module
Figure 9 - Antenna Power Sensor Connections
17. Double check the installation using the interconnection
diagram shown in Figure 10.
18. Set the power switch on the back of the PMU to the
“Off” position.
19. Turn on the main 12V power supply for the cabinet.