Ericsson LBI-39128 Lawn Mower User Manual


 
LBI-39128 INSTALLATION
16
4. Type 8860 and press the Enter key. The Operation
Select Menu should then appear on the terminal as
shown in Figure 15 (revision # and date may be
different). If the PMU does not respond to this entry,
the password may have been re-configured from its
factory default value. See the Erase All Programming
heading in the Maintenance section for the procedure to
return all parameters to the factory default values,
including returning the password to 8860.
5. With the Operational Select Menu shown on the
terminal, type 4 (for item #4 - Setup) and press the
Enter key. The Setup Selection Menu should then
appear on the terminal as shown in Figure 16.
6. With the Setup Selection Menu shown on the terminal,
type 10 (for item #10 - Erase All Programming) and
press the Enter key.
7. At the “Enter Y to Continue, Any Other Character to
Abort:” prompt (after the warning message), type Y and
press the Enter key.
8. At the “Enter Site Password” prompt, type 8860 and
press the Enter key.
9. At the “Enter Site ID” prompt, type 1234 and press the
Enter key. You will be given a 4-second countdown and
then a flashing “Sentry Initialized” message.
10. Finally the Setup Selection Menu should appear on the
terminal.
SENTRY 8860 COPYRIGHT 1987-1994 DECIBEL PRODUCTS
PATENT 4,823,280
OPERATION SELECT MENU SENTRY PMU REV 8.6 12/07/94
1. DISCONNECT
2. REPORTS
3. MANUAL CONTROL
4. SETUP
5. HARDWARE STATUS
6. SOFTWARE STATUS
7. RESET ***WARNING - FOR EMERGENCY ONLY***
ENTER SELECTION:
Figure 15 - Operation Select Menu (Main Menu)
SETUP SELECTION MENU
1. RETURN TO OPERATION SELECT MENU
2. SITE DATA #1
3. SITE DATA #2
4. ANALOG INPUT CHANNEL
5. DIGITAL INPUT CHANNEL
6. ANALOG PSEUDO CHANNEL
7. DIGITAL PSEUDO CHANNEL
8. RELAY OUTPUTS
9. INPUT CONVERSION TABLE
10. ERASE ALL PROGRAMMING
11. db TEST CONFIGURATION
12. db TOWER LIGHTS CONFIGURATION
ENTER SELECTION: _