Bradley Smoker TDB3108 Outdoor Fountain User Manual


 
TDB3108, WF3208 Terreon
®
54" Circular Installation
18 4/6/2007 Bradley Corporation • 215-1187 Rev. N; EN 06-915B
6
Electrical connections for Adaptive Infrared
START-UP NOTE: Do not use for two minutes after making power connection. The sensors will take up
to eight minutes (without being used) to adapt to the bowl if another object is detected during the
two-minute start-up period.
I.R. MODULE
S50-344
TOP VIEW MODULE
ASSEMBLY
CONNECT WIRES
AS SHOWN
VALVE ASSY.
S50-369
110/24 VAC
TRANSFORMER
S83-134
F = FEMALE CONNECT
M = MALE CONNECT
WIRE
ADAPTER
269-620
S53-261
(S53-261A) C
RED
(S53-261A) A
RED
(S53-272) B
BLACK
WINDOW
269-1351
Figure 12
CONNECT THE THREE WIRES FROM THE INFRARED MODULE ASSEMBLY TO THE VALVE ASSEMBLY. ATTACH TWO OF THE FEMALE
CONNECT WIRES TO THE SOLENOIDS AS SHOWN IN FIGURE 12. ATTACH THE MALE CONNECT WIRE TO ONE OF THE 24 VAC
TRANSFORMER LEADS. ATTACH THE REMAINING TRANSFORMER LEAD TO THE SOLENOID WIRE ADAPTER (SEE FIGURE 12).
A
CONNECT 24 VAC TRANSFORMER PROVIDED TO POWER SOURCE.
B
TURN SUPPLIES ON. OPEN CHECK/STOP VALVES COMPLETELY.
C
OPEN VOLUME CONTROL VALVE COMPLETELY AND CHECK PIPING INSTALLATION FOR LEAKS.
D
PASS YOUR HAND IN FRONT OF EACH SENSOR UNTIL AIR IS PURGED FROM THE LINES.
E