Xantrex Technology PV225S-480-P Portable Generator User Manual


 
Operation
2–24 152607
Energize Procedure (Startup)
To start up the PV225S:
1. Remove any lockout devices from the Utility connection circuit breaker and
PV disconnect switch.
2. Close the Utility connection circuit breaker.
3. Close the AC Disconnect Switch.
4. Close DC Disconnect Switch.
5. Turn the
ON/OFF switch to the ON position.
After a 15 second initialization period, the PV225S will automatically transition
to ‘Waking Up’, given the PV voltage is greater than the PV V Start set point.
De-Energize/Isolation Procedure (Shutdown)
The following procedure should be followed to de-energize the PV225S for
maintenance:
To isolate the PV225S:
1. Turn the O
N/OFF switch to the OFF position.
2. Open the DC Disconnect Switch.
3. Open the AC Disconnect Switch.
4. Open the utility connection circuit breaker.
5. Install lockout devices on the utility connection circuit breaker and DC
Disconnect Switch.
WARNING
The terminals of the DC input may be energized if the PV arrays are energized. In
addition, allow 5 minutes for all capacitors within the main enclosure to discharge after
disconnecting the PV225S from AC and DC sources.