0080 Left Matrix Not ON S This fault indicates that the PV225S
has detected that the left IGBT matrix
(FPGA) was not enabled after having
sent a command for it to turn on. The
CCU2 sends an acknowledge bit to
confirm the command is received.
This fault is primarily a watch-dog
between software and hardware to
ensure control of the left IGBT matrix
(FPGA).
Software acknowledge
bit not accepted
FPGA inoperable
0081 Right Matrix Not
ON
S This fault indicates that the PV225S
has detected that the right IGBT
matrix (FPGA) was not enabled after
having sent a command for it to turn
on. The CCU2 sends an acknowledge
bit to confirm the command is
received. This fault is primarily a
watch-dog between software and
hardware to ensure control of the
right IGBT matrix (FPGA).
Software acknowledge
bit not accepted
FPGA inoperable
0084 Left Matrix Not OFF S This fault indicates that the PV225S
has detected that the left IGBT matrix
(FPGA) was not disabled after having
sent a command for it to turn off. The
CCU2 sends an acknowledge bit to
confirm the command is received.
This fault is primarily a watch-dog
between software and hardware to
ensure control of the left IGBT matrix
(FPGA).
Software acknowledge
bit not accepted
FPGA inoperable
0085 Right Matrix Not
OFF
S This fault indicates that the PV225S
has detected that the right IGBT
matrix (FPGA) was not disabled after
having sent a command for it to turn
off. The CCU2 sends an acknowledge
bit to confirm the command is
received. This fault is primarily a
watch-dog between software and
hardware to ensure control of the
right IGBT matrix (FPGA).
Software acknowledge
bit not accepted
FPGA inoperable
Table 4-1
Fault Codes
Error
Code Fault Source(s)
Fault Type
H=Hardware
S=Software
Fault Description Possible Causes