Toshiba VF-nC1 Portable Generator User Manual


 
E6581090
H-2
8
(Continued)
Item
displayed
Key
operated
LED
display
Communication
No.
Description
CPU1
version
X FE08 The version of the CPU1 is displayed.
CPU2
version
XY FE73 The version of the CPU2 is displayed.
Memory
version
XG FE09 The version of the memory mounted is displayed.
Past trip 1 QE ⇔ FE10 Past trip 1 (displayed alternately at 0.5-sec. intervals)
Past trip 2 QJ  ⇔ FE11 Past trip 2 (displayed alternately at 0.5-sec. intervals)
Past trip 3 QR ⇔ FE12 Past trip 3 (displayed alternately at 0.5-sec. intervals)
Past trip 4 PGTT FE13 Past trip 4 (displayed alternately at 0.5-sec. intervals)
Cumulative
operation
time
VQ FE14
The cumulative operation time is displayed.
(0.01 corresponds to 1 hours.)
Default
display
mode
 The operation frequency is displayed (during operation).
Note 1:Press the or key to change items displayed in the status monitor mode.
Note 2:With the current unit selection parameter or voltage unit selection parameter, you can choose
between percentage and ampere (A) for current or between percentage and volt (V) for
voltage, respectively.
Note 3:The input (DC) voltage displayed is 1/
2
times as large as the rectified d.c. input voltage.
Note 4:PGTT is displayed to show the absence of error.
Note 5:The cumulative operation time increments only when the machine is in operation.
Note 5
Note 4
Note 4
Note 4
Note 4
MON