Toshiba VF-nC1 Portable Generator User Manual


 
E6581090
K-10
11
Table of input terminal functions 2
Function
No.
Code Function Action
29 R+SS4
Combination of reverse run and preset
speed command 4
ON :Simultaneous input of R and SS4
commands
30 F+SS1+AD2
Combination of forward run, preset
speed command 1 and
acceleration/deceleration 2
ON :Simultaneous input of F, SS1 and
AD2 commands
31 R+SS1+AD2
Combination of reverse run, preset
speed command 1 and
acceleration/deceleration 2
ON :Simultaneous input of R, SS1 and
AD2 commands
32 F+SS2+AD2
Combination of forward run, preset
speed command 2 and
acceleration/deceleration 2
ON :Simultaneous input of F, SS2 and
AD2 commands
33 R+SS2+AD2
Combination of reverse run, preset
speed command 2 and
acceleration/deceleration 2
ON :Simultaneous input of R, SS2 and
AD2 commands
34 F+SS3+AD2
Combination of forward run, preset
speed command 3 and
acceleration/deceleration 2
ON :Simultaneous input of F, SS3 and
AD2 commands
35 R+SS3+AD2
Combination of reverse run, preset
speed command 3 and
acceleration/deceleration 2
ON :Simultaneous input of R, SS3 and
AD2 commands
36 F+SS4+AD2
Combination of forward run, preset
speed command 4 and
acceleration/deceleration 2
ON :Simultaneous input of F, SS4 and
AD2 commands
37 R+SS4+AD2
Combination of reverse run, preset
speed command 4 and
acceleration/deceleration 2
ON :Simultaneous input of R, SS4 and
AD2 commands
38 FCHG Frequency command forced switching
Enabled if HOQF = 4 (selectable
between terminal board and operation
panel/internal potentiometer)
ON :VI terminal
OFF: Internal potentiometer
39 THR2 No.2 thermal switching
ON :No.2 thermal (RV:, H,
H, H, H)
OFF: No.1 thermal (RV: Setting, XN,
H, XD, VJT)
40 MCHG No.2 motor switching
ON :No.2 motor (
RV
:0,
H
,
H,
H
,
H
,
H
,
H
)
OFF: No.1 motor (Pt: Setting, XN,
H, XD, VJT, CEE,
FGE)
49 HD
Operation holding
(Stop of 3-wire operation)
ON :F (forward run) / R (reverse run)
held, 3-wire operation
OFF:Slowdown stop
54 FreeRun Standby (inversion)
ON :Free run
OFF:Standby
55 RSTN Reset signal (inversion) OFF to ON: Trip reset
56 F+ST
Combination of forward run and standby
commands
ON :Simultaneous input of F and ST
commands
57 R+ST
Combination of reverse run and standby
commands
ON :Simultaneous input of R and ST
commands
*This function is effective after software version V110.
*